DURA-STORM ™ 2000 AND 3000: HURRICANE AUTOMATIC SLIDING DOOR

dura-storm-2000-3000

Automatic Swing Door Operator Systems for Retail Stores, Hospitals, Schools & All Other Public Buildings

The Dura-Storm™ 2000/3000 Hurricane Series is tested to meet the State of Florida’s most stringent building design & code requirements for hurricane force winds and flying debris. The Dura-Storm is trusted as a buildings first line of defense from storms by reducing air infiltration, withstanding high wind pressure and maximizing forced entry resistance. Areas that experience high winds but lack a hurricane specific code can benefit by improving building integrity.

FEATURES AND BENEFITS

  • Full Breakout (3000 only) allows all door panels to be broken out at any point of travel.

    .

  • Partial Breakout (2000 only) allows only sliding panel to break out at any point of travel.

    .

  • All welded panel design
  • Wind resistant dampers reduce the potential for panel damage caused by wind gusts when panels are broken out
  • Reinforced top and bottom pivots
  • Top and bottom panel ball detents
  • Heavy duty security hooks keep the panels on track under high wind load pressure
  • Impact glass is used on “impact rated” products to mitigate potential hazards of flying debris and keeps the interior safe
  • Armored strike utilizes an eight laminate hook with bolt and stile reinforcement for enhanced security
  • Rated for installation in to wood, steel, concrete or aluminum substrates
  • Multi point bolt locking

OPTIONS

  • Clear or Dark Bronze Anodized and Special Finishes
  • Activation and Safety Options
  • Alarm Contacts
  • Emergency Power Options
  • Locking Options
    • Electric Solenoid Lock (Fail Safe/Fail Secure)
    • Surface or Recessed Panic Hardware

DOOR PACKAGE, TYPE, PSF RATING, MAX. DIMENSIONS (WxH), GLASS

2000/3000 Dura-Storm Bi-Parting and Single Slide Impact Series

  • Narrow / Medium Stiles: +/- 75 PSF
  • Bi-part: 168” x 96”
  • Single Slide: 108” x 96”
  • EGlass: 9/16”

2000/3000 Dura-Storm Bi-Parting Impact Series

  • Medium Stiles – Steel Reinforced: +/- 55 PSF
  • Bi-part: 192” x 104” / 179.5” x 128”
  • Glass: 9/16

2000/3000 Dura-Storm Bi-Parting and Single Slide with Transom Option Non-Impact Series

  • Narrow / Medium Stiles: +/- 55 PSF
  • Bi-part: 168” x 96” (w/o transom) or 123.75” (w/ transom)
  • Single Slide with Optional Transom: 108” x 96” (w/o transom) or 123.75” (w/ transom)
  • Glass: ¼”, 1”

All door packages are custom manufactured to fit your job requirements up to ¼” increments. For sizes greater or smaller than typical, contactAUTOMATIC DOORS COMPANY LIMITED today.

DESIGN: Single Slide or Bi-part

BREAKOUT: SX Panel on the 2000, SX and SO panels on the 3000

TYPICAL HEIGHT: 7’-8” (2.3m), Clear Door Opening of 6’-11” (2.1m)

HEADER SIZE: 8” (203mm) High x 6” (152mm) Deep

JAMB DIMENSION: 1 3/4” x 4 1/2” Option: 1 3/4” x 6”

STILES: Narrow 2.0” or Medium 4.0″

TYPICAL DOOR PANEL WEIGHT: Up to 220 Pounds Each (100kg)

MAXIMUM PANEL WEIGHT: Up to 400lb (With Heavy Duty Option)

DOOR PANEL MATERIALS: Aluminum

POWER REQUIRED: 120 VAC, 50/60 HZ, 5 Amps Minimum

DRIVE SYSTEM: 1/4 HP DC Motor, Gear Drive, Toothed belt | OPTION: Twin 1/4 HP DC Gear Driven Motors

CONTROLS: Rocker Switch | OPTION: Rotary, Keyed Rotary Controls, Eco Pro

CONTROLLER: Microprocessor Based, Safety Logic

SENSORS: 2 for Motion (Switchable Between Uni-directional and Bi-directional) and 1 Stan-Guard® and Doorway Holding Beam for Safety | OPTIONAL: Mats, Wallplates, Radio Control

TEMPERATURE RATING: -30F to 130F

GLASS: 1/4″, 1″ | 9/16″ Impact Glass

THRESHOLD: Configurable Options

TRANSOM: Optional on Non Impact package only

CODES AND STANDARDS:ANSI A156.10, NFPA 101, UL, cUL, ICBO, BOCA, Florida Building Code, Miami-Dade County NOA Code Compliance, ASTM E283

GLASS: 1/4″, 1/2″, 5/8″